Art nr MC-75
MC-50
Multifunction pocket calibrator for simultan measurement
SIKA simulators have been developed for simple and flexible calibration and maintenance. Various tests can be performed in a single operation without having to change instruments. This saves time. SIKA multifunction simulators combine the functions of a wide range of individual devices into a single unit.
Resistance thermometer (RTD)
RTD signal generation and measurement: Pt50, Pt100, Pt200, Pt500, Pt1000, Cu10, Cu50, Ni100, Ni120, Ni1000
Ω generator function: 0...4000 Ω
Ω measurement function: 0...4000 Ω
Accuracy (of rdg. + const.): ±0,012 %
Selectable temperature unit: °C / °F
Measurement of multi-wire: 2 / 3 / 4
Thermocouples (TC)
TC signal generation and measurement: J, K, T, R, S, B, N, E, U, L
mV generator function: 0...100 mV
mV measurement function: 0...100 mV
Accuracy (of rdg. + const.): ±0,013 %
Selectable temperature unit: °C / °F
Internal comparison point: ±0,3 °C
Current (mA)
Loop current signal generation: 0(4)...24 mA
Loop current signal measurement: 0(4)...50 mA
Accuracy (of rdg. + const.): ±0,0175 %
Current loop supply: 4 V ±10 %, 22 mA
HART communication protective resistor: 250 Ω
Voltage (V)
Voltage signal generation: 0...20 V
Voltage signal measurement: 0...50 V
Accuracy (of rdg. + const.): ±0,015 %
Continuity (O / C)
Continuity measurement: O / C
Switching threshold open: 1 kΩ
Frequency and pulse (Hz)
Frequency and pulse signal generation: 0,01 Hz...10 kHz
Frequency and pulse signal measurement: 0,01 Hz...20 kHz
Accuracy (of rdg. + const.): ±0,005 %
Pressure signals (bar)
Pressure measurement with external pressure module: yes
Editable pressure units: yes
Connection via DIN socket: 5-pin
Functions at generation
High-speed call values: 10 points (flexible)
Linear steps and ramps: yes
User-defined synthesiser values: 100
User-defined signal output characteristic: 10 points
Editable units: yes
Transmitter function simulation: yes
Functions at measurement
Data memory: 10 000 values
Value tables and graphics function: yes
Offset programming for sensor characteristic: yes
Calibration data files and linearisation points: 5 x 4 values
User-defined measuring input characteristic: 10 points
Editable units: yes
Measured value min. / max.: yes
Averaging function: yes
RTD signal generation and measurement: Pt50, Pt100, Pt200, Pt500, Pt1000, Cu10, Cu50, Ni100, Ni120, Ni1000
Ω generator function: 0...4000 Ω
Ω measurement function: 0...4000 Ω
Accuracy (of rdg. + const.): ±0,012 %
Selectable temperature unit: °C / °F
Measurement of multi-wire: 2 / 3 / 4
Thermocouples (TC)
TC signal generation and measurement: J, K, T, R, S, B, N, E, U, L
mV generator function: 0...100 mV
mV measurement function: 0...100 mV
Accuracy (of rdg. + const.): ±0,013 %
Selectable temperature unit: °C / °F
Internal comparison point: ±0,3 °C
Current (mA)
Loop current signal generation: 0(4)...24 mA
Loop current signal measurement: 0(4)...50 mA
Accuracy (of rdg. + const.): ±0,0175 %
Current loop supply: 4 V ±10 %, 22 mA
HART communication protective resistor: 250 Ω
Voltage (V)
Voltage signal generation: 0...20 V
Voltage signal measurement: 0...50 V
Accuracy (of rdg. + const.): ±0,015 %
Continuity (O / C)
Continuity measurement: O / C
Switching threshold open: 1 kΩ
Frequency and pulse (Hz)
Frequency and pulse signal generation: 0,01 Hz...10 kHz
Frequency and pulse signal measurement: 0,01 Hz...20 kHz
Accuracy (of rdg. + const.): ±0,005 %
Pressure signals (bar)
Pressure measurement with external pressure module: yes
Editable pressure units: yes
Connection via DIN socket: 5-pin
Functions at generation
High-speed call values: 10 points (flexible)
Linear steps and ramps: yes
User-defined synthesiser values: 100
User-defined signal output characteristic: 10 points
Editable units: yes
Transmitter function simulation: yes
Functions at measurement
Data memory: 10 000 values
Value tables and graphics function: yes
Offset programming for sensor characteristic: yes
Calibration data files and linearisation points: 5 x 4 values
User-defined measuring input characteristic: 10 points
Editable units: yes
Measured value min. / max.: yes
Averaging function: yes
There are no accessories available for this product.
There are no consumables available for this product.