Art nr N2014
N2014
Multi-Sensor Temperature Data Logger
The N2014 Multi-Sensor Temperature Data Logger allows you to monitor temperature at up to three different points, with a wide variety of probes making it suitable for applications across food, pharmaceuticals and healthcare.
• Sensor Types: Thermistor, Thermocouple (T & K)
• Monitor up to Three Different Points
• Battery Life: Up to 5 Years
• Warranty: 2 Years
Sensor Type: Thermocouple type T, Thermocouple type K, Thermistor
Measurement Range
Type K: -200°C to +1372°C
Type T: -200°C to +400°C
Thermistor: -40°C to +70°C
Scales: °C and °F
Resolution (Thermocouple):
0.2°C up to and including +300°C
0.5°C above +300°C
Temperature accuracy
+20°C ambient ±0.5°C +0.3% of reading (Logger Only)
-20°C to +40°C ambient ±0.5°C +0.5% of reading (Logger Only)
-40°C to +70°C ambient ±1.0°C +1.0% of reading (Logger Only)
-20°C to +40°C ambient ±0.3°C Thermistor (System Accuracy with Thermistor)
-40°C to +70°C ambient ±0.5°C Thermistor (System Accuracy with Thermistor)
Memory: 32K
1 channel: 16000 samples
2 channels: 8000 samples
3 channels: 5300 samples
4 channels: 4000 samples
Communications: Via infra red interface
Download Time: 3 minutes for 10,000 readings (typical)
Logging Frequency: Programmable between 2 seconds and 99 hours
Internal Sensor Response time: T90 = 15 to 30 minutes in ambient air
Ambient Storage: -40°C to +70°C
Logging Start: Programmable date and time or manual start from instrument multi-function button
Software: Windows™ based software for Windows XP or Vista
Battery Type: 1 x AA size 3.6V replaceable lithium battery
Battery Life: Up to 5 years
Case Material: ABS
Environmental Protection: IP67 BS EN 60529 IEC 529
LED Indication
Dimensions
Length 88mm/3.5ins (including fixing lug)
Width 80mm/3.1ins
Depth 35mm/1.4ins
Measurement Range
Type K: -200°C to +1372°C
Type T: -200°C to +400°C
Thermistor: -40°C to +70°C
Scales: °C and °F
Resolution (Thermocouple):
0.2°C up to and including +300°C
0.5°C above +300°C
Temperature accuracy
+20°C ambient ±0.5°C +0.3% of reading (Logger Only)
-20°C to +40°C ambient ±0.5°C +0.5% of reading (Logger Only)
-40°C to +70°C ambient ±1.0°C +1.0% of reading (Logger Only)
-20°C to +40°C ambient ±0.3°C Thermistor (System Accuracy with Thermistor)
-40°C to +70°C ambient ±0.5°C Thermistor (System Accuracy with Thermistor)
Memory: 32K
1 channel: 16000 samples
2 channels: 8000 samples
3 channels: 5300 samples
4 channels: 4000 samples
Communications: Via infra red interface
Download Time: 3 minutes for 10,000 readings (typical)
Logging Frequency: Programmable between 2 seconds and 99 hours
Internal Sensor Response time: T90 = 15 to 30 minutes in ambient air
Ambient Storage: -40°C to +70°C
Logging Start: Programmable date and time or manual start from instrument multi-function button
Software: Windows™ based software for Windows XP or Vista
Battery Type: 1 x AA size 3.6V replaceable lithium battery
Battery Life: Up to 5 years
Case Material: ABS
Environmental Protection: IP67 BS EN 60529 IEC 529
LED Indication
Dimensions
Length 88mm/3.5ins (including fixing lug)
Width 80mm/3.1ins
Depth 35mm/1.4ins
kalcertLog-ELS-1
E.L.S_7054
ISO17025 temperature calibration certificate - 1 point
kalcertLog-ELS-2
E.L.S_7054
ISO17025 temperature calibration certificate - 2 points
kalcertLog-ELS-3
E.L.S_7054
ISO17025 temperature calibration certificate - 3 points
There are no consumables available for this product.