Automatic Cooled CFPP Analyzer (EN 116)
The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument. The ISL OptiFPP analyzer provides automated CFPP test in strict accordance to EN116 and EN16329 conditions. OptiFPP precisely controls jacket cooling and electronically controlled vacuum adjusts as the test specimen is drawn though a mesh filter, per method conditions. Once crystal formation inhibits sample flow within a set time, a CFPP value is detected, displayed and stored to memory. Detailed reports are available, showing any abnormal points, as well as sample temperature behavior during the test.
ADVANTAGES:
• Ultra low temperature testing capability of diesel fuels (down to -69°C)
• Reliable and precise analysis performance
• Proven and endurance tested for long-term operation
• Stand-alone operation and/or multi-instrument networking (eg printing)
• Full compliance with the EN 16329 standard
• New Touch-Screen and advance electronics
• Electronic vacuum control system with dynamic capabilities
• Compact design with built-in cooler system
• Standard or customized sample cooling profiles (stepped or linear)
• Compact Design with Built-in Cooling System
• Built in QC-Chart for trend monitoring
Customized Test Methods: up to 5 methods (stand-alone mode); unlimited (PC connection)
Analytical principle: Aspiration of cooled diesel and domestic heating fuels through a filter into a volumetric pipette within 60 seconds
Cooling System:
• Internal Stirling Cooling
• Stepped or linear cooling profiles according to method or user defined
• Customizable up to 20 steps
Technical specifications:
Sample Temperature Range: - 95°C to +51°C
Jacket Temperature Range: -105°C to + 55°C, Auto control of programmable cooling steps
Sample temperature Accuracy: 0.1°C Metal/Glass Pt100 probe IEC DIN 751 1/3 class B
Cooling temperature Accuracy: 0.5°C Metal Pt100 probe, Automatic calibration procedure
Sample volume: 45 ml
Power Requirements: 90–240 VAC, (+/- 10 %) V - automatic adaptation, indoors
use only
Environmental Conditions: Operating temp: 10 to 35°C
Storage temp: -20 to 50°C
Frequency: 50/60 Hz
Wattage: 300W
Documentation: Real-time display on screen of test progress & graphics,
QC Database
Internal Memory: 200 test runs with graphic result and cooling curve.
Quality Control Database: Up to 30 QC products with automatic acceptance criteria
PC Networking: IRIS software connection for multi-instrument networking
Printing: Personal/network printer
Display: 7 inch resistive color touch-screen
Data input/output: 2x USB, 1 Ethernet, 1x RS232C serial link for LIMS or external
PC
Password securty: multi-level
Dimensions L x W x H: 600 x 254 x 350 mm
Weight: 30 kg
Accessories included:
1209-010-000 OptiFPP Measuring Head
2205-010-001 CFPP Pipette, 20ml
3001-010-1036 5 test jar holder
3003-010-1062 Cleaning chamber cover
3801-110-004 OptiFPP head Glassware temperature sensor
5201-000-000 Torx Driver
J01028 Power Cord for Continental Europe
J01062 Power Cord for US
M004234 3 x Test tube
M006111 Plastic Tubing D8x4 (This will change)
M01125 2 x Solvent Beaker Stoppers
Q0330303 Pack of 10 filters gauze
Q2210401 Insulation ring and spacers
V033102 Complete Filter Unit
USB Key (documentation)
Quick Start Guide
Test Certificate
2 Years warranty