All-in-one analyzer for Marine Fuels
Super fast speed - Four different tests in less than 25 minutes
-Automatic sample input: no pipette or syringe required. A new vial injection
system loads sample automatically.
-Self cleaning; no solvent required - Cost savings of solvent usage and time
savings as resources can be used for more productive activities. The next fuel is
used to flush and clean the system.
-No external chiller - Quiet, cool, self-contained thermoelectric cooler; no
hazardous liquid bath medium (methanol toxicity)
-No breakable glassware - Internal capillary system eliminates need for fragile
glass viscosity tubes
-Superior precision - Best measured repeatability and reproducibility of any
automatic or manual method
-One-touch preset Favorites - Frequently-used test settings can be stored in the
analyzer for quick access. Favorites can be created, organized, sorted or deleted
as you desire. With the single push of a button, lab operators can efficiently
perform tests in significantly less time
-Optimized for quality control - Automatic QC runs with instantaneous control
charts. Retest sample option increases confidence in test result.
-Easy-to-use interface; intuitive and easy to understand
-Full-color, touch-sensitive, 15” high resolution screen
-USB and Ethernet connectivity
-Programmable user access levels streamlines workflow and prevents accidental
changes
-Import and store any user documents for customized operating procedures (SOP) or training
-Configurable desiccant replacement count
-Customizable reporting - test history, plot data and self-diagnostics can be
displayed on-screen, printed, or transferred to computer for statistical analysis,
presentations, email sharing, archival storage
-Test uses small sample volume
Test methods
Pour Point: ASTM D97, ASTM D5949, IP 15, ISO 3016
Cloud Point: ASTM D2500, ASTM D5773, IP 219, IP 446, ISO 3015
Viscosity: ASTM D7945, ASTM D445, IP 71, ISO 3104
Density: ASTM D4052, IP 365, ISO 12185
Precision
Pour Point Repeatability 1,6°C
Pour Point Reproducibility 3,2°C
Clound point Repeatability 1,3°C - Reproducibility 2,5°C
Kinematic Viscosity Repeatability 0.50% - Reproducibility 0.80%
Density: Repeatability 0,0001g/mL - Reproducibility 0,0005g/mL
Detection
CP/PP: Diffusive Light Scattering (DLS)
Viscosity: Horizontal Capillary using constant gas pressure
Density: Oscillating U-tube
Cooling System
Internal Peltier Cooler
Linear cooling profiles according to test method
Optional user defined, customizable stepped cooling profiles
Test Interval
Pour Point: programmable 1 to 5°C in step of 0.5°C.
Cloud Point: automatic 0.1°C or according to test method.
Viscosity: +40.0 °C according to test method
Density: standard at +15.0 °C
System Cleaning
Automatic flush cycle; no solvent required
Application range
Sample: - 80 to +70°C
°C or °F configurable
Test duration
Cloud & Density combined: 8 to 10 minutes
Viscosity & Density combined: <10 minutes
Cloud, Pour, Viscosity, Density combined: <25 minutes
Operator time: 0,5 minutes
Electrical
90V to 280 VAC; 47-63Hz; 350W
Ambient Conditions
Temperature: max. 10° to 30°C; extremes not recommended
Dimensions
54.6 cm deep x 33.7 cm wide x 44.5 cm high
Weight
Unit: 24 kg (53 lb.)
Boxed: 28 kg (62 lb.)